Solis hybrid inverter reference imageSolis hybrid inverter reference image
Reference image. Confirm the pictured model and supplied configuration before selection.

Hybrid inverter

Solis S6-EH1P8K-L-PLUSHybrid inverter

An 8 kW single-phase low-voltage energy-storage inverter with dual MPPT, up to four PV input strings and dual backup ports described by the manufacturer.

Rated output power
8 kW
MPPT number / maximum input strings
2 / 4
Battery voltage range
40-60 V

8 kW energy-storage inverter.

The source identifies the model as an 8 kW single-phase low-voltage energy-storage inverter.

01

Single-phase energy storage

Assess the 8 kW single-phase model against the project load and local connection requirements.

02

PV input planning

Use the 90-435 V MPPT range and 2 / 4 MPPT and string arrangement as inputs to array design.

03

Backup planning

Review the 8 kW back-up output and less than 4 ms switch-time value in the project design.

Product specifications

Technical specifications.

Review the current product values below, then use the full datasheet and project configuration process for final engineering decisions.

PV input

Recommended maximum PV array size16 kW
Maximum usable PV input power12.8 kW
MPPT voltage range90-435 V
MPPT number / maximum input strings2 / 4

Battery

Battery typeLi-ion / Lead-acid
Battery voltage range40-60 V
Maximum charge / discharge power8 kW
Maximum charge / discharge current190 A

AC and backup

Rated output power8 kW
Rated grid voltage220 / 230 V
Backup rated output power8 kW
Backup switch timeLess than 4 ms
Maximum efficiency96.2 %

Installation

Ingress protectionIP66
Dimensions335 × 560 × 253 mm
Weight23.5 kg
Cooling conceptIntelligent fan-cooling

Values are from the S6-EH1P8K-L-PLUS datasheet, p. 2.

Source: Solis S6-EH1P8K-L-PLUS datasheet ↗

Project configuration

Confirm system compatibility.

Confirm PV, battery and local connection requirements before installation.

  1. 01

    PV array

    Confirm array voltage and proposed string arrangement against the 90-435 V range and 2 / 4 input layout.

  2. 02

    Battery interface

    Confirm the selected battery type, 40-60 V voltage range, and 190 A maximum charge or discharge current.

  3. 03

    Installation

    Confirm site conditions, enclosure placement, wiring and local requirements before installation.

Request a configuration

Start with the project inputs that matter.

Share site and project details so the engineering team can review the requirements and next configuration step.

  • 1Site type and project country
  • 2Load profile and energy requirements
  • 3Grid connection and installation conditions
  • 4Required quantity and delivery timing

Request a quote

Tell us what you need. We reply within one business day.

Product questions

Before project review.

What is the rated output power?

The grid-side rated output power is 8 kW.

How many MPPT and input strings are listed?

The datasheet lists 2 MPPT and a maximum of 4 input strings.

What battery range is listed?

The stated battery voltage range is 40-60 V. Listed battery types are Li-ion / Lead-acid.

What is the stated backup switch time?

The datasheet states less than 4 ms.

What should be confirmed before installation?

Confirm PV, battery, connection and site requirements for the specific project before installation.

top

Start your OEM / ODM project

Tell us about your product and volumes. Our OEM team replies within one business day.

Who you are
Your OEM / ODM project

Request a quote