Inverter and charging functions
Combines inverter, solar charger and battery charger functions in the EM Series platform.
EM SeriesInverter / charger
A 5.5 kW inverter/charger with a 48 V battery interface, pure sine wave AC output and built-in MPPT solar charging. Review the PV array, battery settings and load requirements before selection.
The EM Series combines inverter, solar charger and battery charger functions. Use the model-specific limits below when reviewing the system.
Combines inverter, solar charger and battery charger functions in the EM Series platform.
The EM5500-48 model specifies a 48 VDC battery interface with CC/CV charging. Confirm the battery manufacturer's charging requirements before connection.
Rated capacity is 5.5 kVA / 5.5 kW, with 220/230 VAC ±5% nominal output. Check both running loads and starting requirements.
Product specifications
Review the current product values below, then use the full datasheet and project configuration process for final engineering decisions.
| Rated capacity | 5.5 kVA / 5.5 kW |
|---|---|
| Nominal output voltage | 220/230 ±5% VAC |
| Surge power | 11000 VA |
| Output frequency | 50/60 Hz |
| Output waveform | Pure sine wave |
| Transfer time | 10 ms (personal computer); 20 ms (home appliances) |
| Peak efficiency: PV to inverter | 96 % |
| Peak efficiency: battery to inverter | 93 % |
| Overload protection | 5 s at ≥150% load; 10 s at 110%-150% load |
| Crest factor | 3:1 |
| Admissible power factor | 0.6-1 (inductive or capacitive) |
| Nominal input voltage | 230 VAC |
|---|---|
| Acceptable input voltage | 170-280 VAC (personal computer); 90-280 VAC (home appliances) |
| Input frequency | 50/60 (auto sensing) Hz |
| Battery voltage | 48 VDC |
|---|---|
| Floating charge voltage | 54 VDC |
| Overcharge protection voltage | 63 VDC |
| Charging method | CC/CV |
| Solar charger type | MPPT |
|---|---|
| Maximum PV array power | 5500 W |
| Maximum PV open-circuit voltage | 500 VDC |
| PV MPPT voltage range | 120-450 VDC |
| Maximum solar input current | 18 A |
| Maximum solar charge current | 100 A |
| Maximum AC charge current | 60 A |
| Maximum charge current | 100 A |
| Dimensions (D × W × H) | 438 × 295 × 105 mm |
|---|---|
| Package dimensions (D × W × H) | 560 × 375 × 185 mm |
| Net weight | 9 kg |
| Communication interface | RS232 |
| Operating temperature | -10 to 50 °C |
|---|---|
| Storage temperature | -15 to 50 °C |
| Relative humidity | 5%-95%, non-condensing |
EM5500-48 column and shared rows, datasheet p. 1. The EM3500-24 specifications do not apply. Charge-current limits are listed separately, not added together.
Source: Product parameter source ↗
Project configuration
Confirm PV string voltage, battery charge limits and starting loads with the project engineer. The datasheet does not establish grid-export approval or local certification.
Check cold-weather string open-circuit voltage against the 500 VDC maximum and keep operation within the 120-450 VDC MPPT range.
Confirm battery voltage, permitted charge voltage and current. The 100 A maximum charge current is not the sum of the solar and AC charge-current limits.
Review starting loads, AC input range, ambient conditions and required local approvals. Do not assume grid-export capability from a product label.
Request a configuration
Share the site and project details so the engineering team can review the requirements and next configuration step.
Tell us what you need. We reply within one business day.
Product questions
This page uses the EM5500-48 column of the EM Series datasheet: 5.5 kVA / 5.5 kW rated capacity and a 48 VDC battery interface. The EM3500-24 column describes a different model.
The datasheet specifies a 48 VDC battery interface and CC/CV charging. It does not establish compatibility with every 48 V battery. Confirm charge voltage, current limits and battery manufacturer requirements for the supplied configuration.
No. The datasheet lists 500 VDC as the maximum PV array open-circuit voltage. The MPPT voltage range is 120-450 VDC. Review the complete PV string design against both limits.
No. The datasheet separately lists 100 A maximum solar charge current, 60 A maximum AC charge current and 100 A maximum charge current. These are distinct limits, not an additive 160 A charging rating.
No grid-export approval or local grid certification is established by this datasheet. Confirm the required operating mode, equipment approval and local connection rules before designing a grid-connected project.
Review battery storage and inverter options for your project.
Continue your comparison
Review two relevant alternatives before confirming system architecture and project requirements.
View all products →GENIXGREEN UKRAINE
LiFePO4 battery and hybrid inverter systems, designed and manufactured in our own factory since 2011, now with local warehouse support for Ukraine.
Support
Questions about equipment operation, error messages or warranty.
leo.zhou@genixgreen.comTell us about your product and volumes. Our OEM team replies within one business day.
Tell us what you need. We reply within one business day.