12S system configuration
System values are limited to the 12S configuration.
Tower-HV series referenceCommercial energy storage
An indoor 614.4 V, 100 Ah energy storage rack system based on a 12S configuration. Confirm complete system compatibility with the selected PCS.
Use only after the complete battery system and compatible PCS are selected together.
System values are limited to the 12S configuration.
The source has dedicated component tables for the module and PDU.
The source lists indoor installation and IP20 protection.
Product specifications
Review current values with the full datasheet and project configuration.
| System nominal energy | 61.44 kWh |
|---|---|
| System rated voltage | 614.4 V |
| Battery chemistry | LiFePO4 |
| Module nominal energy | 5.12 kWh |
| Module nominal voltage | 51.2 V |
| Rated capacity | 100 Ah |
| Battery module quantity | 12 |
| System operating voltage | 537.6-691.2 V |
| System discharge energy | 58.98 kWh |
| Rated charge/discharge current | 50 A |
| Overload current | 125 (10 sec, 25°C) A |
| Communication protocol | CAN 2.0 |
| Maximum charge/discharge current | 100 A |
| Protection grade | IP20 |
| Operating temperature range | -10 to 55 °C |
| Installation location | Indoor |
| Cycle life | >=8000 (25°C ±2°C, 0.5C, 80% DoD @65% EOL) cycles |
| PDU model | HV-PDU 750VDC100A |
|---|---|
| Battery module model | HV-Tower-16S100 |
Values are for the 12S system configuration and the separately listed battery module and PDU. Confirm the complete battery and PCS configuration before selection.
Project configuration
Verify PCS voltage range, current limits, communications and indoor installation conditions before procurement.
Match the 537.6-691.2 V range to the selected PCS.
Review rated and maximum current for the project.
Confirm the selected battery module, PDU and PCS configuration for the project.
Request a configuration
Share site and project details for requirement review.
Tell us what you need. We reply within one business day.
Product questions
This record is limited to the Tower-HV-614V100Ah (12S) configuration.
No. It is system nominal energy; the source separately lists 58.98 kWh system discharge energy.
No. Confirm complete-system compatibility with the selected PCS.
No. It is a separate maximum charge/discharge-current row.
Provide the intended system configuration, selected PCS, site conditions and required quantity for project review.
Review battery storage and inverter options for your project.
Continue your comparison
Review two relevant alternatives before confirming system architecture and project requirements.
View all products →GENIXGREEN UKRAINE
LiFePO4 battery and hybrid inverter systems, designed and manufactured in our own factory since 2011, now with local warehouse support for Ukraine.
Support
Questions about equipment operation, error messages or warranty.
leo.zhou@genixgreen.comTell us about your product and volumes. Our OEM team replies within one business day.
Tell us what you need. We reply within one business day.