{"id":90018,"date":"2026-06-28T00:00:00","date_gmt":"2026-06-28T00:00:00","guid":{"rendered":"https:\/\/genixenergy.com.ua\/?p=90018"},"modified":"2026-07-05T22:05:34","modified_gmt":"2026-07-05T14:05:34","slug":"backup-time","status":"publish","type":"glossary","link":"https:\/\/genixenergy.com.ua\/ru\/glossary\/backup-time\/","title":{"rendered":"\u0412\u0440\u0435\u043c\u044f \u0440\u0435\u0437\u0435\u0440\u0432\u043d\u043e\u0433\u043e \u043f\u0438\u0442\u0430\u043d\u0438\u044f"},"content":{"rendered":"<div class=\"vgblk-rw-wrapper limit-wrapper\"><p class=\"gloss-def\">Backup time is the number of hours a battery system can power a defined set of home loads during a grid outage, calculated as usable energy in kWh divided by average load in kW.<\/p>\n\n<p>Because both inputs vary with every home and every scenario, backup time is never a fixed specification of the battery itself. The same system gives very different runtimes depending on which loads are connected.<\/p>\n\n<h2>Why it matters for home backup power<\/h2>\n\n<p>Backup time is the practical outcome that home battery sizing works toward. It connects stored energy to real demand: how many hours will the system run the refrigerator, the router, the lights, and the boiler pump before it needs a recharge? Getting this number right requires knowing both what is connected and how much energy the battery can actually deliver.<\/p>\n\n<p>A planning mistake that recurs in sizing conversations is treating a capacity figure as a runtime. A 10 kWh battery does not deliver &#8220;10 hours of backup.&#8221; It delivers roughly 8.5 kWh of usable energy, and the hours that buys depend entirely on load. At 500 W, that is about 17 hours; at 2 kW, about 4 hours. Connecting a high-draw appliance can halve the expected runtime in minutes.(<a href=\"https:\/\/batteryuniversity.com\/article\/bu-808-how-to-prolong-lithium-based-batteries\" rel=\"noopener noreferrer\" target=\"_blank\">Source: Battery University BU-808<\/a>)<\/p>\n\n<h2>Backup Time in practice<\/h2>\n\n<h3>Key numbers<\/h3>\n\n<p>The formula: backup time (h) = usable energy (kWh) \/ average load (kW)<\/p>\n\n<p>Usable energy is not nameplate capacity. For a LiFePO4 system at 80 to 95 percent <a href=\"\/glossary\/dod\/\">depth of discharge (DoD)<\/a> and 90 to 95 percent inverter efficiency, usable energy is about 85 percent of nameplate. Genixgreen LiFePO4 home systems run at a nominal 51.2 V and scale from about 5 <a href=\"\/glossary\/kwh\/\">kWh<\/a> to 16 kWh. On a 10 kWh system, the usable planning figure is roughly 8.5 kWh.<\/p>\n\n<h3>Load profile decides the runtime<\/h3>\n\n<p>Two homes with identical batteries get different backup times if their <a href=\"\/glossary\/critical-loads\/\">critical loads<\/a> differ. An apartment keeping only a refrigerator, router, and lighting draws roughly 300 to 500 W; a home also running a boiler pump and several device chargers may draw 1 to 1.5 kW. Sizing for backup time therefore starts from a load audit, not from a product catalogue. Confirm the DoD setting in the system BMS before using nameplate capacity in any sizing calculation, because a lower DoD directly reduces available runtime.<\/p>\n\n<h2>How Genixgreen uses Backup Time<\/h2>\n\n<p>Genixgreen has built LiFePO4 storage in its own factory since 2011 and ships to 100+ countries, with local stock in Odesa for delivery across Ukraine. Genixgreen product specifications list nameplate and usable capacity, not a fixed backup-hours figure, because an honest runtime depends on each home&#8217;s load profile. The 6000+ cycle rating means the runtime calculation you perform at installation remains reliable for years of daily use.<\/p>\n\n<h2>Related terms<\/h2>\n\n<ul>\n  <li><a href=\"\/glossary\/critical-loads\/\">Critical Loads<\/a>: the appliance set whose wattage forms the denominator in the backup-time formula<\/li>\n  <li><a href=\"\/glossary\/kwh\/\">kWh<\/a>: the energy unit used to express both nameplate and usable capacity for the numerator<\/li>\n  <li><a href=\"\/glossary\/dod\/\">Depth of Discharge (DoD)<\/a>: the fraction of nameplate capacity that is usable; a higher DoD means more runtime per cycle<\/li>\n  <li><a href=\"\/product\/\">Genixgreen home battery range<\/a>: systems from 5 kWh to 16 kWh with published usable capacity figures<\/li>\n  <li><a href=\"\/glossary\/\">Full glossary<\/a>: all energy storage terms in the Genixgreen glossary<\/li>\n<\/ul>\n\n<h2>Sources<\/h2>\n\n<ul>\n  <li>Battery University BU-808: How to prolong lithium-based batteries (DoD, usable capacity, efficiency). <a href=\"https:\/\/batteryuniversity.com\/article\/bu-808-how-to-prolong-lithium-based-batteries\" target=\"_blank\" rel=\"noopener\">https:\/\/batteryuniversity.com\/article\/bu-808-how-to-prolong-lithium-based-batteries<\/a><\/li>\n<\/ul>\n\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"DefinedTerm\",\n      \"@id\": \"https:\/\/genixenergy.com.ua\/en\/glossary\/backup-time\/#term\",\n      \"name\": \"Backup Time\",\n      \"alternateName\": [\"battery runtime\", \"backup duration\"],\n      \"termCode\": \"backup-time\",\n      \"description\": \"Backup time is the number of hours a battery system can power a defined set of home loads during a grid outage, calculated as usable energy in kWh divided by average load in kW.\",\n      \"inDefinedTermSet\": {\n        \"@type\": \"DefinedTermSet\",\n        \"@id\": \"https:\/\/genixenergy.com.ua\/en\/glossary\/#set\",\n        \"name\": \"Genixgreen Energy Storage Glossary\"\n      },\n      \"inLanguage\": \"en\"\n    },\n    {\n      \"@type\": \"Article\",\n      \"@id\": \"https:\/\/genixenergy.com.ua\/en\/glossary\/backup-time\/#article\",\n      \"headline\": \"Backup Time: definition, formula and how to calculate battery runtime for your home\",\n      \"about\": { \"@id\": \"https:\/\/genixenergy.com.ua\/en\/glossary\/backup-time\/#term\" },\n      \"author\":    { \"@id\": \"https:\/\/genixenergy.com.ua\/en\/#organization\" },\n      \"publisher\": { \"@id\": \"https:\/\/genixenergy.com.ua\/en\/#organization\" },\n      \"isPartOf\":  { \"@id\": \"https:\/\/genixenergy.com.ua\/en\/#website\" },\n      \"datePublished\": \"2026-06-28\",\n      \"dateModified\": \"2026-06-28\",\n      \"inLanguage\": \"en\"\n    }\n  ]\n}\n<\/script>\n<\/div><!-- .vgblk-rw-wrapper -->","protected":false},"excerpt":{"rendered":"<p>\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0447\u0430\u0441\u043e\u0432, \u0432 \u0442\u0435\u0447\u0435\u043d\u0438\u0435 \u043a\u043e\u0442\u043e\u0440\u044b\u0445 \u0430\u043a\u043a\u0443\u043c\u0443\u043b\u044f\u0442\u043e\u0440 \u043f\u0438\u0442\u0430\u0435\u0442 \u0434\u043e\u043c \u0432\u043e \u0432\u0440\u0435\u043c\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f, \u0432 \u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e\u0441\u0442\u0438 \u043e\u0442 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438.<\/p>","protected":false},"featured_media":0,"template":"","glossary_cat":[54],"class_list":["post-90018","glossary","type-glossary","status-publish","hentry","glossary_cat-performance-sizing"],"_links":{"self":[{"href":"https:\/\/genixenergy.com.ua\/ru\/wp-json\/wp\/v2\/glossary\/90018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/genixenergy.com.ua\/ru\/wp-json\/wp\/v2\/glossary"}],"about":[{"href":"https:\/\/genixenergy.com.ua\/ru\/wp-json\/wp\/v2\/types\/glossary"}],"wp:attachment":[{"href":"https:\/\/genixenergy.com.ua\/ru\/wp-json\/wp\/v2\/media?parent=90018"}],"wp:term":[{"taxonomy":"glossary_cat","embeddable":true,"href":"https:\/\/genixenergy.com.ua\/ru\/wp-json\/wp\/v2\/glossary_cat?post=90018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}